LPV Series Closed Circuit Axial Piston Pump
Closed Circuit Axial Piston Pump advantage
kEY PARAMETERS
Features
Features
Product Specifications
Rated |
|
30 |
50 |
70 |
90 |
110 |
130 |
160 |
180 |
200 |
|
Maximum displacement |
ml/r |
30 |
50 |
70 |
90 |
110 |
130 |
160 |
180 |
200 |
|
Speed |
Maximum continuous operating speed |
r/min |
3500 |
3500 |
3200 |
3000 |
2900 |
2700 |
2400 |
2400 |
2400 |
Rated speed |
r/min |
2500 |
2200 |
||||||||
Minimum continuous operating speed |
r/min |
500 |
|||||||||
Pressure |
Rated working pressure |
Mpa |
35 |
||||||||
Maximum working pressure (instantaneous) |
Mpa |
42 |
|||||||||
Continuous working pressure ( Δ P) |
Mpa |
30 |
|||||||||
Allowable shell pressure (absolute) |
Mpa |
Constant0.25,Peak value0.5 |
|||||||||
Torque |
Continuous output torque |
Nm |
162.3 |
252.3 |
342.6 |
432.9 |
535.3 |
632.4 |
776 |
875 |
972 |
Maximum output torque |
Nm |
227 |
353 |
480 |
606 |
749 |
885 |
1000 |
1098 |
1200 |
|
Power |
Continuous Power |
KW |
41 |
72 |
98 |
128 |
137 |
162 |
191 |
224 |
279 |
Maximum power |
KW |
57 |
87 |
105 |
138 |
159 |
188 |
292 |
307 |
318 |
|
Temperature |
Allowable temperature of shell |
℃ |
80 |
||||||||
Maximum operating temperature of fuel tank |
℃ |
70 |
|||||||||
Angle |
Maximum inclination angle of the inclined plate |
° |
± 18 ° |
||||||||
Weight |
LPV series hydraulic pump Hydraulic oil drainage |
kg |
44 |
45 |
62.5 |
63.5 |
71 |
96 |
98 |
140 |
144 |
detail displaY
Product Application
Packing & Delivery
To protect the goods, we pack and fix goods at least two layers. The first layer is plastic bag to protect against moisture, the second is to fix hydrostatic pump in the plywood case because its heavy goods, the third is plywood case, standard export package.
FAQ
ADD:No. 2 Tianchen Road, Yucheng High-tech Zone, Shandong